Our sensors are guaranteed to
keep their performance for at least 10 sterilization runs.
Applikon will replace the sensor free of
charge upon inspection of the sensor once we ensure there has been no
physical damage to the sensor.
We pride ourselves that the shelf life of the sensor is for
a minimum of 2 years, so a large number can be ordered at any time
without fear of losing their viability over time.
pH+ gel electrodes:
+Automatic (re-)pressurization at every sterilization
(AppliSens Patent)
=> low and constant offset => no need to recalibrate
=> no ingress of media into sensor => no cross contamination
=> sensor not pressurized on stock => no loss of reference gel
=> sensor not pressurized on stock => no cutting needed to activate
+Titanium shield on pH+ electrode:
=> no electromagnetic interference on sensor signal => stable signal
=> no electromagnetic interference on sensor signal => quicker calibration
and the ground glass diaphragm
The standard porous ceramic diaphragm
found in most manufacturer's sensors is replaced by a glass-glass sleeve
diaphragm, resulting in virtually:
· no protein fouling
· no offset error
· no drift
· no need for lengthy chemical storage to
clean your sensor
For more detailed information on how to store your
sensors, calibrate, autoclaving and general "won't find it in the manual"
information, please send us an e-mail, requesting our "Laboratory Hints"
packet.
| |
1L Applikon
|
3 and 5L Applikon
3L NBS
3/5 Braun
|
5L Applikon
3L NBS
3/5 Braun
|
5L Applikon
7.5 NBS
6.6 NBS
5.0 Braun
|
7 and 15L Applikon
20/70/110L BioClave
14L NBS
|
SIP
|
| PH+ |
|
|
|
|
|
|
| 235 mm |
·
|
·
|
|
|
|
|
| 325 mm |
|
|
·
|
·
|
|
|
| 425 mm |
|
|
|
|
·
|
|
| 590 mm |
|
|
|
|
·
|
|
| 120 mm |
|
|
|
|
|
·
|
| |
|
|
|
|
|
|
| DO sensor |
|
|
|
|
|
|
| 235 mm |
·
|
·
|
|
|
|
|
| 325 mm |
|
|
·
|
·
|
|
|
| 385 mm |
|
|
|
·
|
|
|
| 590 mm |
|
|
|
|
·
|
|
| 650 mm |
|
|
|
|
·
|
|
| 800 mm |
|
|
|
|
·
|
|
| 65 mm |
|
|
|
|
|
·
|
| 110 mm |
|
|
|
|
|
·
|
|
AppliSens Part #
|
pH+
sensors
|
|
Z001012051
|
Sensor pH+ 120mm 1-3L Vessel
Assembly
|
|
Z001023551
|
Sensor pH+ 235mm 2-5 L Vessel
Assembly
|
|
Z001032551
|
Sensor pH+ 325mm 2-5 L Vessel
Assembly
|
|
Z001042551
|
Sensor pH+ 425mm 5-10 L Vessel
Assembly
|
|
Z001059051
|
Sensor pH+ 590mm 10-20L Vessel
Assembly
|
|
|
|
|
AppliSens Part
#
|
LowDrift
DO sensors (12 mm Diameter)*
|
|
Z010023520
|
Sensor
DO 110 mm 1L Vessel Assembly or Side entry for SIP unit
|
|
Z010023520
|
Sensor DO 235 mm 2-5 L Vessel Assembly
|
|
Z010032520
|
Sensor DO 325 mm 2-5 L Vessel Assembly
|
|
Z010038520
|
Sensor DO 385 mm 5 -7 L Vessel Assembly
|
|
Z010059020
|
Sensor DO 590 mm 10-20 L Vessel Assembly
|
|
Z010065020
|
Sensor DO 650 mm 20-70 L Vessel Assembly
|
|
Z010080020
|
Sensor DO 800 mm 70-110 L BioClave
|
|
AppliSens Part
#
|
Cables pH / Redox
/ DOLow (for 2-pin sensors)
|
|
Z100200010
|
Cable pH/ DOLow sensor L=2.0m BNC
|
|
Z100380010
|
Cable pH/ DOLow sensor L=3.8m BNC
|
|
Z100500010
|
Cable pH/ DOLow sensor L=5.0m BNC
|
|
Z100200020
|
Cable for pH sensor + S-connector,
2.0m
|
|
Z100500020
|
Cable for pH sensor + S-connector,
5.0m
|
|
Z100200011
|
Cable T-pull pH/DOLow , L=2.0m, BNC
|
|
Z100380011
|
Cable T-pull pH/DOLow , L=3.8m, BNC
|
|
Z100500011
|
Cable T-pull pH/DOLow , L=5.0m, BNC
|
|
Z100006010
|
Cable converter K9 ßà S7 pH sensor
|
|
Z100200030
|
Cable pH sensor DIN-plug, L=2.0m
|
|
Z100380030
|
Cable pH sensor DIN-plug, L=3.8m
|
|
Z110200030
|
Cable DOLow (2-pin) Lemo-plug, L=2.0m
|
|
Z110380030
|
Cable DOLow (2-pin) Lemo-plug, L=3.8m
|
|
|
DO
sensor accessories
|
|
Z110000420
|
Membrane kit Diss.Oxygen Titanium
|
|
Z110002510
|
Electrolyte Dis.Oxygen sensor 250ml
|
|
Z110005010
|
Electrolyte Dis.Oxygen sensor 50ml
|
|
*Z110009010
|
Cable converter 2Pßà 4P DO sensor2-pin sensor to
pre-existing 4-pin cable
|
|
Z110001000
|
Membrane Test Kit DO sensor
|
|
Z110001010
|
AUTOCLAVABLE Polarization Module 4Pin DO sensor
|
|
Z110001020
|
AUTOCLAVABLE Polarization Module 2Pin Low Drift
DOLow sensor
|
|
|
|
|
|
Sensor Holders
|
|
Z100002520
|
Sensor holder DN25 L=120 TracFix A
|
|
Z100002530
|
Sensor holder DN25 L=154 TracFix B
|
|
Z101002510
|
Sensor holder DN25 L=120 EasyFix A
|
|
Z101002511
|
Sensor holder DN25 L=120 EasyFix A with glass bulb
protection guard
|
|
Z101002520
|
Sensor holder DN25 L=120 EasyFix B
|
|
Z101002521
|
Sensor holder DN25 L=120 EasyFix B with glass bulb
protection guard
|
|
|
type B holders => these are
only for Braun fermentors with a sanitary port
|
|
Z100001810
|
Sensor holder M18 - PG13.5
|
|
Z100002710
|
Sensor holder D27 - PG13.5
|
PH+ Cables for all Applikon BioBundles, Braun Biostat I and NBS
BioFlo 110 and BioFlo 3000 series:
Z10020010
Z100380010
Z100500010 Cables (difference is length). These are for both pH+
and DO (2 pin sensors). BNC connection
Gel-filled pH+ electrodes: long-life, stable
zero-point and slope
The precision of pH+ measurement in the
pharmaceutical industry is vital as it directly affects production, stability
and analysis of the active ingredients.
Non-Toxic
The AppliSens gel filled pH+ sensors are
manufactured using a non-toxic gel (see also the Material Safety Datasheet).
Long-Life
All AppliSens electrodes are delivered with the Long-Life system to prevent
silver/protein interference on the diaphragm.
Protection
The AppliSens pH+ sensors are provided with a Ti layer on the innertube
meaning there's no window between sensor head and gel which results in
an excellent screen (protection against electro magnetic interference).
The gelfilled pH+ electrodes are filled with a completely non-toxic
gel *no side-effects whatsoever.
GLP
All electrodes are accompanied by a certificate: good for GLP. All AppliSens
sensors do have a Long-Life code print (engraved serial number) on the
sensor head (good for validation; FDA / GLP). All pH+ sensors delivered
have already been autoclaved.
Easy Handling
The PG 13.5 connector is NOT integrated into the electrode head (free
spinning). This makes the electrode much easier to handle. A special type
is available with which the PG 13.5 connector is integrated with the electrode
head (like with BJC and Ingold)
|